1. Taw qhia
The Nova IceProbe Thermoelectric Aquarium Chiller is designed to provide a reliable cooling solution for small aquariums. Utilizing advanced thermoelectric technology, this unit efficiently converts electricity into cooling power to maintain desired water temperatures. This manual provides essential information for the proper installation, operation, and maintenance of your IceProbe chiller.
2. Cov ntaub ntawv kev nyab xeeb
- Ib txwm txiav lub hwj chim ua ntej ua kev kho lossis kev teeb tsa.
- Xyuas kom lub hwj huam mov voltage matches the chiller's requirements (120V).
- Do not operate the chiller if the power cord or plug is damaged.
- Keep the chiller's fan area clear of obstructions to ensure proper airflow and prevent overheating.
- This device is intended for indoor use with aquariums only.
- A drip loop should be created for all power cords to prevent water from traveling along the cord and reaching electrical outlets.
3. Cov ntsiab lus ntawm pob
Thaum qhib lub pob, xyuas kom meej tias tag nrho cov khoom muaj nyob thiab tsis muaj kev puas tsuaj:
- Nova IceProbe Thermoelectric Aquarium Chiller unit
- Watertight securing nut
- Silicon washer
- Power cord (5' 9" length)
- Probe cord (6' length)
4. Cov lus qhia tshwj xeeb
| Qauv nab npawb | IPAC-50W-120V |
| Dimensions (Unit with probe) | 4" (W) x 4 3/4" (D) x 7 1/2" (H) |
| Fais fab Cord Length | 5' 9" |
| Kev sojntsuam Cord Length | 6' |
| Chaw tsim tshuaj paus | NOVA TEC |
| Lub Tebchaws Keeb Kwm | Tuam Tshoj |
5. Teeb cov lus qhia
The IceProbe chiller is designed for easy integration into various aquarium setups, including siphon overflows, prefilters, sumps, or directly into plastic aquariums. Installation requires drilling a 1 1/4" hole.
- Prepare the Installation Location: Identify a suitable location for the chiller. This could be a bulkhead in a sump, an overflow box, or a drilled hole in a plastic aquarium wall. Ensure there is at least 3-1/8" minimum interior clearance for the cooling probe and 1" air circulation space around the exterior fan unit.
- Tho Lub Qhov: Carefully drill a 1 1/4" diameter hole at the chosen installation point. Ensure the hole is clean and free of debris.
- Insert qhov kev sojntsuam: Insert the cooling probe through the drilled hole from the inside of the aquarium/sump.
- Ruaj ntseg lub tshuab: Place the silicon washer over the probe on the exterior side of the aquarium/sump, followed by the watertight securing nut. Tighten the nut firmly by hand to create a secure, watertight seal. Do not overtighten.
- Position the Chiller: Ensure the exterior fan unit is positioned to allow for adequate airflow. The fan should not be obstructed.
- Connect to Temperature Controller: The IceProbe chiller does not have an integrated on/off switch or temperature controller. It provides continuous chilling when powered. To regulate the aquarium temperature, you yuav tsum connect the chiller to a separate, external temperature controller (not included). This controller will turn the chiller on and off based on your set temperature parameters.
- Kev sib txuas fais fab: Once the chiller is securely installed and connected to a temperature controller, plug the temperature controller into a power outlet. Ensure a drip loop is formed with the power cord.


6. Cov lus qhia ua haujlwm
The IceProbe chiller operates continuously when powered. Its cooling function is managed by an external temperature controller. Follow these guidelines for optimal performance:
- Kev tswj qhov kub thiab txias: Set your desired temperature range on your external temperature controller. The controller will activate the chiller when the water temperature exceeds the upper limit and deactivate it when the temperature falls below the lower limit.
- Cooling Peev Xwm: The cooling capacity of a single IceProbe unit varies with water volume and ambient air temperature. Refer to the "Typical Temperature Pulldown" chart below for estimated performance.
- Ntau Chav: For larger aquariums or greater temperature reduction, multiple IceProbe units can be used.
- Airflow: Ensure the fan on the exterior unit has unrestricted airflow. Blocked airflow will reduce cooling efficiency and may lead to overheating.
Typical Temperature Pulldown (°F)

| Chillers | Gallons dej | ||
|---|---|---|---|
| 10 | 20 | 40 | |
| 1 | 6-8 : kuv | 3-4 : kuv | 1-2 : kuv |
| 2 | 10-12 : kuv | 6-8 : kuv | 3-4 : kuv |
Note: These values are approximate and can vary based on ambient room temperature, aquarium insulation, water circulation, and other environmental factors.
7. Kev tu
Regular maintenance ensures the longevity and efficient operation of your IceProbe chiller.
- Ntxuav Ntxuam: Periodically inspect the fan on the exterior unit for dust and debris accumulation. Gently clean with a soft brush or compressed air to ensure optimal airflow.
- Inspect the Probe: Check the cooling probe inside the aquarium for any algae or mineral buildup. Clean gently with a soft cloth or sponge if necessary.
- Tshawb xyuas kev sib txuas: Ensure all electrical connections are secure and the watertight securing nut remains tight.
- Dej Zoo: Maintaining good aquarium water quality will help prevent excessive buildup on the cooling probe.
8. Kev daws teeb meem
If you encounter issues with your IceProbe chiller, consider the following common troubleshooting steps:
- Chiller Not Cooling:
- Verify the chiller is receiving power from the temperature controller.
- Check the temperature controller settings to ensure it is set to activate the chiller.
- Ensure the fan on the exterior unit is spinning and not obstructed.
- Confirm the cooling probe is submerged in water.
- Check for excessive dust or debris on the fan or cooling probe.
- Kev ua kom txias tsis txaus:
- Ensure adequate air circulation around the exterior fan unit.
- Verify the aquarium size is within the recommended cooling capacity (refer to the "Typical Temperature Pulldown" chart). For larger tanks or greater temperature drops, consider adding a second IceProbe unit.
- Check ambient room temperature; higher room temperatures will reduce cooling efficiency.
- Ensure the cooling probe is clean and free of buildup.
- Suab nrov txawv txawv:
- Inspect the fan for any obstructions or loose components.
- Xyuas kom tseeb tias lub tshuab tau teeb tsa ruaj khov thiab tsis co rau lwm qhov chaw.
Yog tias cov kauj ruam daws teeb meem tsis daws qhov teeb meem, thov hu rau kev pabcuam rau cov neeg siv khoom.
9. Warranty Information
The Nova IceProbe Thermoelectric Aquarium Chiller unit comes with a one-year warranty against defects in materials and workmanship from the date of purchase. This warranty covers manufacturing defects under normal use. It does not cover damage resulting from misuse, neglect, improper installation, accidents, or unauthorized repairs.
For warranty claims, please retain your proof of purchase and contact customer support.
10. Cov neeg siv khoom txhawb nqa
For technical assistance, troubleshooting guidance beyond this manual, or warranty inquiries, please contact NOVA TEC customer support. Refer to the manufacturer's website lossis cov khoom ntim rau cov ntaub ntawv tiv tauj tam sim no.
Chaw tsim tshuaj paus: NOVA TEC