1. Taw qhia

This manual provides essential information for the safe installation, operation, and maintenance of the Pilz PNOZ X3P Safety Relay, model 777314. The PNOZ X3P is designed for monitoring E-STOP pushbuttons, safety gates, and light grids in industrial applications, ensuring personnel and machine safety.

2. Cov lus qhia kev nyab xeeb

CEEB TOOM: Failure to follow these safety instructions can result in serious injury or death, and damage to equipment.

  • Only qualified personnel familiar with industrial safety standards and electrical systems should install, operate, or maintain this device.
  • Disconnect all power before performing any installation, wiring, or maintenance tasks.
  • Xyuas kom txhua txoj hlua hluav taws xob ua raws li cov cai hluav taws xob hauv zos thiab hauv teb chaws.
  • Do not bypass or disable safety functions.
  • Regularly inspect the device and associated safety components for damage or malfunction.
  • Use only genuine PILZ replacement parts.

3. Khoom Tshajview

The Pilz PNOZ X3P (Model 777314) is a safety relay designed for monitoring safety functions. It features:

  • Muaj nuj nqi: E-STOP, safety gate, light grid monitoring.
  • Tiv tauj Configuration: 3 Normally Open (NO) safety contacts, 1 Normally Closed (NC) auxiliary contact, 1 Semiconductor Output (SO).
  • Muab Voltage Ntau Yam: 24-240VAC/DC (Coil Voltage: 24V AC/DC).
  • Hom kev ua haujlwm: Tsis siv neeg rov pib dua.
  • Dav: 45mm ib.
Pilz PNOZ X3P Safety Relay, front view with terminals and indicators

Daim duab 1: Pem hauv ntej view of the Pilz PNOZ X3P Safety Relay, showing terminals and indicators.

4. Kev teeb tsa thiab kev teeb tsa

4.1 Mounting

Mount the PNOZ X3P on a 35mm DIN rail in a control cabinet. Ensure adequate ventilation around the device to prevent overheating. Maintain proper clearance from heat-generating components.

4.2 Kev sib txuas hluav taws xob

Before making any electrical connections, ensure the main power supply is disconnected and locked out. Refer to the wiring diagrams for correct terminal assignments.

5. Thaiv

The PNOZ X3P supports 1-channel or 2-channel wiring for safety inputs. The choice depends on the required safety integrity level (SIL) and performance level (PL).

5.1 Input Wiring (E-STOP, Safety Gate, Light Grid)

  • 1-Channel Wiring: Connect the safety device (e.g., E-STOP) to a single input channel. This configuration offers basic safety.
  • 2-Channel Wiring: Connect the safety device to two independent input channels. This configuration provides redundancy and higher fault tolerance, suitable for higher safety requirements.

5.2 Output Wiring

The relay provides 3 NO safety contacts for controlling power to hazardous machinery and 1 NC auxiliary contact for signaling purposes. The 1 SO (semiconductor output) can be used for diagnostic feedback to a PLC.

Ensure that the load connected to the safety contacts does not exceed the maximum switching current of 15 Amps and maximum switching voltage 240v.

Fig 2: Example wiring diagram for a 2-channel E-STOP application. (Actual diagram not provided, refer to product documentation for specific wiring.)

6. Cov lus qhia ua haujlwm

The PNOZ X3P operates in an automatic reset mode. Once the safety input circuit is closed (e.g., E-STOP released, safety gate closed), the safety relay will automatically energize its output contacts, provided no faults are detected.

6.1 Fais fab-Up

Upon applying power, the relay performs an internal self-test. If the safety inputs are closed and no faults are present, the output contacts will close, and the status indicators will illuminate.

6.2 Safety Function Activation

When a safety input is opened (e.g., E-STOP pressed, safety gate opened), the PNOZ X3P immediately de-energizes its safety output contacts, bringing the monitored machine to a safe state.

6.3 Rov Mus Dua

Due to its automatic reset function, the relay will re-energize its outputs as soon as the safety input circuit is restored and no faults are present. Ensure that the machine can only restart safely after a reset.

7. Kev tu

Regular maintenance is crucial to ensure the continued safe operation of the PNOZ X3P safety relay.

  • Kev tshuaj xyuas lub sijhawm: Visually inspect the device and its wiring for any signs of damage, loose connections, or contamination.
  • Functional Test: Periodically test the entire safety circuit, including the PNOZ X3P, by activating the connected safety devices (E-STOP, safety gate, light grid) to verify their proper function.
  • Ntxuav: Keep the device free from dust and debris. Use a dry, soft cloth for cleaning. Do not use abrasive cleaners or solvents.

8. Kev daws teeb meem

If the safety relay does not function as expected, consider the following common issues:

Teeb meemUa TauKev daws
Outputs do not energize after power-up.
  • Tsis muaj hluav taws xob.
  • Safety inputs open (e.g., E-STOP pressed).
  • Kev txhaum sab hauv.
  • Check power connections and voltage.
  • Ensure all safety inputs are closed.
  • Contact PILZ technical support.
Outputs de-energize unexpectedly.
  • Safety input opened momentarily.
  • Xoo hluav taws xob.
  • Kev cuam tshuam.
  • Check safety devices for intermittent operation.
  • Inspect all wiring connections.
  • Ensure proper grounding and shielding.

If troubleshooting steps do not resolve the issue, contact PILZ technical support.

9. Kev qhia tshwj xeeb

ParameterTus nqi
Qauv777314
HomPILZ
Hom kev ua haujlwmTsis siv neeg
Coil Voltage24 Volts (AC/DC)
Hu rau qhov ntsuas tam sim no6 Amps
Qhov siab tshaj plaws hloov tam sim no15 Amps
Qhov siab tshaj plaws Hloov Voltage240 Volts
Yam Nyhav0.64 Ib

10. Warranty thiab Support

PILZ products are manufactured to high-quality standards and come with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the official PILZ website lossis hu rau koj tus neeg muag khoom hauv zos.

For technical assistance, product support, or to report a malfunction, please contact PILZ customer service. Have your product model (777314) and serial number ready when contacting support.

PILZ Official Webqhov chaw: www.pilz.com ua

© 2024 PILZ. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.