Sib 1172/45

Urmet Bibus Comfort 1172/45 Intercom System User Manual

Qauv: 1172 / 45 | Hom Tshuaj: Urmet

1. Taw qhia

This manual provides detailed instructions for the installation, operation, and maintenance of your Urmet Bibus Comfort 1172/45 intercom system. This system is designed to provide reliable communication and door entry control, featuring 6 distinct melodies for call signaling. Please read this manual thoroughly before attempting installation or operation to ensure proper function and safety.

2. Cov ntaub ntawv kev nyab xeeb

Yuav tsum ua raws li kev ceev faj txog kev nyab xeeb hauv qab no los tiv thaiv kev raug mob thiab kev puas tsuaj rau lub cuab yeej:

  • Kev teeb tsa yuav tsum tau ua los ntawm tus kws tshaj lij hluav taws xob tsim nyog raws li cov cai hluav taws xob hauv zos.
  • Tua hluav taws xob ua ntej ua kev teeb tsa, kev saib xyuas, lossis kev daws teeb meem.
  • Tsis txhob tso lub cuab yeej kom ya raws, qhov kub thiab txias, lossis ncaj qha tshav ntuj.
  • Tsis txhob sim qhib lossis kho lub cuab yeej koj tus kheej. Xa tag nrho cov kev pabcuam rau cov neeg ua haujlwm tsim nyog.
  • Use only Urmet approved accessories and spare parts.

3. Cov ntsiab lus ntawm pob

Xyuas kom tseeb tias txhua yam khoom muaj nyob hauv pob:

  • Urmet Bibus Comfort 1172/45 Intercom Unit
  • Mounting Bracket
  • Mounting Screws thiab Phab Ntsa Plugs
  • Tus Neeg Siv Los Siv (cov ntawv no)
Urmet Bibus Comfort 1172/45 Intercom Unit

Figure 1: Urmet Bibus Comfort 1172/45 Intercom Unit. This image displays the main intercom unit, typically a rectangular device with a speaker, microphone, and call button, designed for indoor use.

4. Kev teeb tsa thiab kev teeb tsa

Follow these steps for proper installation of the Urmet Bibus Comfort 1172/45 intercom system:

  1. Kev npaj: Ensure the power supply to the installation area is disconnected at the main circuit breaker.
  2. Mounting:
    • Select a suitable indoor location, away from direct heat sources or moisture.
    • Use the mounting bracket as a template to mark drilling points on the wall.
    • Drill holes and insert wall plugs. Secure the mounting bracket to the wall using the provided screws.
  3. Kev xaim:
    • Connect the system wiring to the terminals on the intercom unit according to the wiring diagram provided in the separate installation guide (if applicable) or on the unit itself. Pay close attention to polarity.
    • Xyuas kom tag nrho cov kev sib txuas yog ruaj ntseg thiab insulated.
  4. Kev sib dhos zaum kawg: Carefully attach the intercom unit to the mounted bracket, ensuring it clicks securely into place.
  5. Hwj chim On: Restore power to the system. The unit should power on, indicated by a status light (if present).

5. Cov lus qhia ua haujlwm

The Urmet Bibus Comfort 1172/45 is designed for straightforward operation:

5.1 Tau Txais Kev Hu

  • When a visitor presses the call button on the outdoor unit, the indoor intercom unit will ring with one of the 6 pre-programmed melodies.
  • To answer the call, lift the handset (if applicable) or press the talk button.
  • To end the call, replace the handset or press the talk button again.

5.2 Qhov Rooj Tso Tawm

To open the door for a visitor:

  • During an active call, press the door release button (usually marked with a key symbol).
  • The door will unlock for a short period, allowing the visitor to enter.

5.3 Melody Selection (if applicable)

Some models allow selection of the ringing melody. Refer to the specific controls on your unit. Typically, a small switch or button allows cycling through the 6 available melodies.

6. Kev tu

The Urmet Bibus Comfort 1172/45 requires minimal maintenance:

  • Ntxuav: Wipe the unit with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Kev tshuaj xyuas: Periodically check for loose connections or visible damage. If any damage is found, disconnect power and contact a qualified technician.

7. Kev daws teeb meem

If you encounter issues with your intercom system, refer to the following table:

Teeb meemUa TauKev daws
No sound from intercom unit.No power; loose wiring; faulty unit.Check power supply; verify wiring connections; contact support if unit is faulty.
Qhov rooj tso tawm tsis ua haujlwm.Wiring issue to door strike; faulty door strike; faulty intercom unit.Check wiring to door strike; test door strike independently; contact support.
Intercom rings continuously or not at all.Stuck call button on outdoor unit; wiring fault; unit malfunction.Inspect outdoor unit button; check wiring; contact support.

If the problem persists after attempting these solutions, please contact Urmet customer support.

8. Cov lus qhia tshwj xeeb

  • Qauv: Urmet Bibus Comfort 1172/45
  • Melodies: 6 xaiv tau
  • Fais fab mov: (Typically 12-24V AC/DC, specific to Bibus system - information not provided)
  • Qhov Loj: (information not provided)
  • Qhov hnyav: Approximately 150 kg (Note: This weight from product data is unusually high for an intercom unit and may be a data entry error. Please refer to the product packaging for accurate weight information.)
  • Ua haujlwm kub: (information not provided)

Note: The listed item weight of 150 kg from the product specifications is unusually high for an intercom unit and may be a data entry error. Please refer to the product packaging for accurate weight information.

9. Warranty thiab Support

Urmet products are covered by a limited warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Urmet website. For technical support, spare parts, or service inquiries, please contact your local Urmet distributor or customer service center.

Urmet Customer Service:

  • Webqhov chaw: www.urmet.com
  • Tiv tauj xov tooj: Xa mus rau lub website kom paub meej txog kev sib cuag hauv cheeb tsam.

© 2024 Urmet. All rights reserved. Information in this manual is subject to change without notice.