Fatek FBs-20MNR2-AC (FBs-20MN)

Fatek PLC Controller FBs-20MNR2-AC User Manual

Model: FBs-20MNR2-AC (FBs-20MN)

1. Taw qhia

This manual provides essential information for the proper installation, operation, and maintenance of the Fatek FBs-20MNR2-AC Programmable Logic Controller (PLC). The FBs-20MNR2-AC is a compact and powerful controller designed for industrial automation applications, offering a robust set of features for various control tasks.

Please read this manual thoroughly before attempting to install or operate the device to ensure safe and efficient use.

2. Cov yam ntxwv tseem ceeb

  • 2 points digital differential input + 2 points digital differential output (920KHz 5VDC)
  • 10 points 24VDC digital input (4 points with 200KHz)
  • 6 Points relay digital output
  • 1 built-in RS-232 communication port (expandable up to 5 ports)
  • Built-in real-time calendar function
  • Wide power supply range: 100~240VAC
  • UL certified for safety and quality assurance

3. Cov ntaub ntawv kev nyab xeeb

Ua raws li kev tiv thaiv kev nyab xeeb hauv qab no los tiv thaiv tus kheej raug mob thiab kev puas tsuaj rau cov khoom siv:

  • Kev Nyab Xeeb Hluav Taws Xob: Ensure all power is disconnected before wiring or performing any maintenance. Only qualified personnel should perform electrical installations.
  • Grounding: Properly ground the PLC to prevent electrical shock and ensure stable operation.
  • Ib puag ncig: Install the PLC in an environment free from excessive dust, moisture, corrosive gases, and extreme temperatures.
  • Qhov cua: Ensure adequate ventilation around the PLC to prevent overheating.
  • Kev xaim: Use appropriate wire gauges and terminal connections. Do not exceed specified current ratings for inputs and outputs.
  • Emergency Stop: Always incorporate an independent emergency stop circuit in your system design.

4. Kev teeb tsa thiab kev teeb tsa

4.1 Kev teeb tsa lub cev

The FBs-20MNR2-AC PLC is designed for DIN rail mounting within an industrial control panel. Ensure sufficient clearance for wiring and heat dissipation.

4.2 Kev Txuas Txuas Txuas

Refer to the diagram below for terminal identification and wiring connections. Ensure all connections are secure and correct before applying power.

Fatek PLC Controller FBs-20MNR2-AC showing input/output terminals, power connections, and communication ports.

Daim duab 1: Pem hauv ntej view of the Fatek FBs-20MNR2-AC PLC, illustrating the various input (X), output (Y), power (AC100-240V, L, N, GND), and communication (TX, RX, PORTO) terminals. The status indicators (POW, RUN, ERR) are also visible.

4.2.1 Kev Siv Hluav Taws Xob

  • Connect the AC power supply (100-240VAC) to the L (Line) and N (Neutral) terminals.
  • Connect the protective earth ground to the (Ground) terminal.

4.2.2 Digital Input Wiring (X0-X13)

  • The PLC features 10 points of 24VDC digital input (X0-X9), with X0-X3 supporting high-speed 200KHz operation.
  • Additionally, there are 2 points of digital differential input (X0-X1, X2-X3) for high-speed applications up to 920KHz.
  • Connect input devices (e.g., sensors, switches) to the respective X terminals.

4.2.3 Digital Output Wiring (Y0-Y9)

  • The PLC provides 6 points of relay digital output (Y0-Y5).
  • There are also 2 points of digital differential output (Y0-Y1, Y2-Y3) for high-speed applications up to 920KHz.
  • Connect output devices (e.g., relays, contactors, indicator lights) to the Y terminals. Observe the maximum current rating for each output.

4.2.4 Communication Port (PORTO, RS-232)

  • The built-in RS-232 port (PORTO) is used for programming the PLC and communicating with other devices.
  • Connect a programming cable from your computer to this port.

5. Cov lus qhia ua haujlwm

5.1 Fais fab tuag

After completing all wiring and ensuring safety, apply power to the PLC. The POW indicator LED should illuminate, indicating that the unit is receiving power.

5.2 Programming the PLC

The Fatek FBs-20MNR2-AC is programmed using specific PLC programming software (e.g., WinProladder). Connect the PLC to your computer via the RS-232 port and use the software to develop, download, and monitor your control programs.

5.3 Cov cim xwm txheej

  • POW (Power): Illuminates when power is supplied to the PLC.
  • RUN (Run Mode): Illuminates when the PLC is executing the user program.
  • ERR (Error): Illuminates or flashes to indicate a system error or fault. Refer to the troubleshooting section for details.
  • TXL (Transmit): Flashes when data is being transmitted via the communication port.
  • RX (Tau Txais): Flashes when data is being received via the communication port.

6. Kev tu

Regular maintenance ensures the longevity and reliable operation of your PLC.

  • Ntxuav: Periodically clean the exterior of the PLC with a soft, dry cloth. Do not use solvents or abrasive cleaners. Ensure power is off before cleaning.
  • Kev Tshuaj Xyuas Qhov Kawg: Regularly check all wiring terminals for tightness and corrosion. Loose connections can lead to intermittent operation or damage.
  • Environmental Check: Verify that the operating environment remains within specified conditions (temperature, humidity, dust).
  • Hloov tshiab Firmware: Xyuas cov chaw tsim khoom website for any available firmware updates that may improve performance or address issues. Follow update instructions carefully.

7. Kev daws teeb meem

Tshooj lus no muab kev daws teeb meem rau cov teeb meem uas koj yuav ntsib.

Teeb meemUa TauKev daws
PLC does not power on (POW LED off).No power supply, incorrect wiring, or internal fault.Check AC power connections (L, N, Ground). Verify power source. Ensure wiring is correct. If problem persists, contact support.
RUN LED is off, but POW LED is on.No program loaded, program error, or PLC in STOP mode.Download a valid program to the PLC. Check for program errors in the software. Ensure the PLC is set to RUN mode via software.
ERR LED is illuminated or flashing.System error, hardware fault, or critical program error.Connect to the PLC with programming software to read the error code. Consult the software manual for specific error meanings and solutions.
Inputs (X) are not responding.Incorrect wiring, faulty sensor, or input device not supplying correct voltage.Verify input device wiring and functionality. Check input voltage levels. Ensure input addresses in the program match physical connections.
Outputs (Y) are not activating.Incorrect wiring, faulty output device, or program logic error.Verify output device wiring and functionality. Check program logic for output activation conditions. Ensure output addresses in the program match physical connections.
Communication issues (e.g., cannot connect to PLC).Incorrect cable, wrong port settings, or driver issues.Ensure correct RS-232 cable is used. Verify COM port settings (baud rate, parity, data bits, stop bits) in software match PLC settings. Install or update USB-to-serial drivers if applicable.

8. Kev qhia tshwj xeeb

SpecificationTus nqi
Qauv nab npawbFBs-20MNR2-AC (FBs-20MN)
Digital Inputs10 points 24VDC (4 points 200KHz), 2 points differential (920KHz 5VDC)
Digital Outputs6 points relay output, 2 points differential (920KHz 5VDC)
Kev sib txuas lus Ports1 built-in RS-232 (expandable up to 5)
Fais fab mov100 ~ 240VAC
Built-in ntaReal-time calendar
Cov ntawv pov thawjUL tau ntawv pov thawj
Pob Dimensions4.5 x 4 x 4 po
Yam Nyhav1.01 Ib
Chaw tsim tshuaj pausFatek
Hnub Ua Ntej MuajCuaj hlis 27, 2015

9. Warranty thiab Support

For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Fatek directly. Technical support can be obtained through your authorized Fatek distributor or by visiting the official Fatek website for contact information and resources.

Always provide your product model number (FBs-20MNR2-AC) and serial number when seeking support.

© 2023 Fatek. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.