Daitsu DS-12 UDIN

Daitsu DS-12 UDIN Wall-Split Inverter Air Conditioner User Manual

1. Taw qhia

This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your Daitsu DS-12 UDIN Wall-Split Inverter Air Conditioner. Please read this manual thoroughly before using the appliance and keep it for future reference. This unit is designed to provide both cooling and heating functions for optimal indoor climate control.

2. Cov ntaub ntawv kev nyab xeeb

Yuav tsum ua raws li cov kev tiv thaiv kev nyab xeeb hauv qab no los tiv thaiv kev raug mob lossis kev puas tsuaj rau lub tsev:

  • Installation must be performed by a qualified professional in accordance with local electrical and safety regulations.
  • Do not attempt to repair or modify the unit yourself. Contact authorized service personnel for all repairs.
  • Xyuas kom tseeb tias lub hwj chim muab hluav taws xob phim cov lus qhia teev nyob rau ntawm daim ntawv teev npe ntawm lub tshuab.
  • Tsis txhob ntxig ntiv tes lossis cov khoom rau hauv qhov cua nkag / qhov hluav taws xob.
  • Khaws cov khoom tawg yooj yim kom deb ntawm chav tsev.
  • Regularly clean the air filter to maintain efficiency and air quality.
  • If abnormal operation, strange sounds, or smoke occurs, immediately turn off the unit and disconnect the power supply.

3. Khoom Tshajview

The Daitsu DS-12 UDIN is a wall-mounted split-system air conditioner consisting of an indoor unit and an outdoor unit. It features inverter technology for energy-efficient climate control.

Daitsu DS-12 UDIN indoor unit

Image: The Daitsu DS-12 UDIN indoor unit, showcasing its sleek white design and 'inverter' and 'daitsu' branding.

Daitsu DS-12 UDIN indoor unit with display

Duab: pem hauv ntej view of the Daitsu DS-12 UDIN indoor unit with its digital display showing '25' degrees Celsius, indicating current temperature or setting.

Angled view of Daitsu DS-12 UDIN indoor unit

Duab: Angled view of the Daitsu DS-12 UDIN indoor unit, highlighting its modern design and the digital temperature display.

Unit Dimensions:

  • Chav Nyob Sab Hauv Tsev: Qhov siab 275 hli x Dav 790 hli x Qhov tob 200 hli
  • Chav sab nraum zoov: Qhov siab 596 hli x Dav 842 hli x Qhov tob 320 hli

4. Kev teeb tsa thiab kev teeb tsa

Installation of the Daitsu DS-12 UDIN split-system air conditioner requires specialized knowledge and tools. It is strongly recommended that installation be carried out by a certified HVAC professional to ensure proper functioning, safety, and compliance with warranty conditions.

Cov ntsiab lus tseem ceeb ntawm installation:

  • Qhov chaw: Xaiv ib qho chaw rau cov chav tsev sab hauv tsev thiab sab nraum zoov uas tso cai rau huab cua zoo tshaj plaws, tsawg kawg nkaus kev thaiv, thiab yooj yim nkag mus rau kev saib xyuas.
  • Mounting: Securely mount the indoor unit on a wall and the outdoor unit on a stable surface or wall bracket.
  • Refrigerant Piping: Connect the indoor and outdoor units with appropriate refrigerant piping, ensuring proper insulation and leak-free connections.
  • Dej ntws: Install a drainage pipe for condensate water from the indoor unit.
  • Kev sib txuas hluav taws xob: Connect the unit to a dedicated power supply circuit as per electrical codes. Ensure proper grounding.
  • Vacuuming and Refrigerant Charge: The system must be thoroughly vacuumed to remove air and moisture before charging with the correct amount of refrigerant (R32).

5. Cov lus qhia ua haujlwm

Your Daitsu DS-12 UDIN air conditioner offers various modes and functions for customized comfort. Control is typically managed via a remote control (not detailed in this manual).

Operating range and function icons

Image: Visual representation of the operating temperature range and various function icons including Turbo, Swing, Dry, Timer, Light, Sleep, 4 Speeds, X-FAN, Test, Start, Intelligent Defrosting, and Lock.

Main Operating Modes:

  • Txias hom: Reduces room temperature to the desired setting.
  • Cua sov hom: Increases room temperature to the desired setting.
  • Hom Qhuav: Ua kom huab cua qhuav, txo cov av noo.
  • Hom Ntxuam: Circulates cua tsis txias los yog cua sov.

Tshwj xeeb muaj nuj nqi:

Detailed descriptions of operating functions

Image: Detailed descriptions of various operating functions: Turbo, Active Carbon Filter, Swing, Dry, Timer, Light, Sleep, Four Air Speeds, X-FAN, Test, Start, Intelligent Defrosting, Reset, and Lock.

  • Turbo Muaj nuj nqi: Rapidly increases cooling or heating capacity to reach the desired temperature quickly.
    Turbo function diagram

    Image: Diagram illustrating the 'TURBO' function, which rapidly increases cooling capacity to reach the desired temperature quickly.

  • Swing Function: Automatically moves the air outlet louvers vertically to distribute air evenly.
  • Dry Function: Txo cov av noo hauv chav.
  • Timer: Allows programming of operation for up to 24 hours.
  • Lub teeb: Turns off all indicator lights on the indoor unit display.
  • Pw tsaug zog muaj nuj nqi: Adjusts room temperature for optimal comfort and energy saving during sleep.
  • Four Air Speeds: High for rapid dehumidification, Medium for normal operation, Low for silent operation, and Auto option to select appropriate speed.
  • X-FAN Function: Ensures the internal unit's heat exchanger is dried to prevent mold formation.
    X-FAN function diagram

    Image: Diagram showing the 'X-FAN' function, which eliminates residual humidity to prevent mold formation on the heat exchanger, keeping the unit clean and healthy.

  • Test Function: Checks the appliance's operation and displays error codes on the indoor unit panel.
  • Start Function: The indoor unit fan only activates when the heat exchanger reaches the ideal temperature.
  • Intelligent Defrosting: An intelligent defrosting system that activates only when necessary, significantly increasing energy savings and comfort.
  • Xauv muaj nuj nqi: Locks the remote control settings to prevent accidental changes.

6. Kev tu

Kev saib xyuas tsis tu ncua yuav ua kom koj lub tshuab cua txias ua haujlwm tau ntev thiab ua haujlwm tau zoo. Ib txwm txiav hluav taws xob ua ntej ua kev saib xyuas.

Cua Lim Cleaning:

  • Qhib lub vaj huam sib luag pem hauv ntej ntawm chav tsev sab hauv.
  • Tshem tawm cov lim cua.
  • Siv lub tshuab nqus tsev los ntxuav cov lim dej los yog ntxuav nrog dej sov so (qis dua 40°C).
  • Allow filters to dry completely in a shaded area before reinstalling.
  • Cov lim dej huv txhua ob lub lis piam lossis ntau zaus nyob ntawm kev siv thiab huab cua zoo.

Chav tsev Deg Cleaning:

  • So cov khoom sab hauv tsev thiab sab nraum zoov nrog ib daim ntaub mos mos, damp daim ntaub.
  • Do not use harsh detergents, abrasive cleaners, or solvents, as these can damage the plastic parts.

Kev saib xyuas raws caij nyoog:

  • At the beginning of each season (cooling/heating), check for any obstructions around the outdoor unit.
  • Xyuas kom tseeb tias cov yeeb nkab dej ntws tawm huv si thiab tsis raug thaiv.
  • Consider professional inspection and cleaning annually.

7. Kev daws teeb meem

Ua ntej hu rau kev pabcuam, thov xyuas cov teeb meem hauv qab no:

  • Chav tsev tsis pib: Check if the power plug is securely inserted, the circuit breaker is tripped, or the remote control batteries are dead.
  • Tsis txaus txias/cua sov: Ensure air filters are clean, windows and doors are closed, and there are no obstructions to airflow. Check if the temperature setting is appropriate.
  • Cov suab nrov txawv txawv: A slight gurgling sound is normal due to refrigerant flow. Loud or persistent noises may indicate an issue.
  • Water leakage from indoor unit: Check if the drainage hose is blocked or kinked.

If the problem persists after checking these points, or if an error code is displayed (use the Test function), please contact a qualified service technician. Do not attempt to repair the unit yourself.

8. Cov lus qhia tshwj xeeb

Technical data for the Daitsu DS-12 UDIN Wall-Split Inverter Air Conditioner.

Technical data sheet for Daitsu DS-12 UDIN

Image: Technical data sheet for the Daitsu DS-12 UDIN, detailing power, efficiency, sound levels, and refrigerant type.

FeatureSpecification
HomDaitsu
Qauv Lub NpeDS-12 UDIN (ASD12UI DN)
Tshooj Naj Npawb3NDA8325
HomWall-Split Inverter Air Conditioner
Lub peev xwm txias3.2 kW (Min 0.6 - Max 3.6 kW) / 12000 BTU / 1 Ton
Lub peev xwm cua sov3.4 kW (Min 0.6 - Max 3.8 kW)
SEER (Seasonal Energy Efficiency Ratio)6.1
SCOP (Seasonal Coefficient of Performance)4.0
Energy Label (Cooling/Heating)A+++ / A+
PDesign (Cooling/Heating)3.2 kW / 3.2 kW
Indoor Unit Sound Pressure (A/M/B)42/37/35 dBA
Outdoor Unit Sound Pressure52 dBA ua
Indoor Unit Airflow (Max/Min)560/410 m³ / h
Outdoor Unit Airflow2200 m³ / h
Fais fab mov230V / 1 Phase / 50 Hz
Absorbed Power (Cooling/Heating)0.99 kW / 0.94 kW
Annual Energy Consumption (Cooling/Heating)184 kWh/a / 1120 kWh/a
Pipe Diameter (Liquid/Gas)6.35mm / 9.52mm
Tub yees homR32 (GWP approx. 675) (Note: Technical sheet image indicates R410A, please verify with product label)
Pre-charge / Max. Pipe Length5 m / 15 m
Operating Range (Cooling)-15 ° C txog 43 ° C
Operating Range (Heating)-15 ° C txog 24 ° C
Qhov Loj ntawm Chav Tsev Sab Hauv Tsev (H x W x D)275 x 790 x 200 mm
Qhov Loj ntawm Chav Sab Nraud (H x W x D)596 x 842 x 320 mm
XimDawb
Txoj Kev Txhim KhoSplit-system

9. Warranty thiab Support

For warranty information, please refer to the warranty card included with your product or contact your local Daitsu dealer. Keep your purchase receipt as proof of purchase.

For technical support, service requests, or spare parts, please contact the authorized Daitsu service center in your region. Do not attempt to service the unit yourself.

Daitsu DS-12 UDIN User Manual | © 2023 Daitsu. All rights reserved.