1. Taw qhia
The OWON OW18E is a high-precision 4½ digit digital multimeter designed for accurate electrical measurements. With a 20,000-count display and True RMS capability, it provides reliable readings for various waveforms. This device integrates Bluetooth 4.0 for wireless data transfer and logging, enhancing efficiency in diverse applications such as research, manufacturing, and maintenance. Its robust design, safety features, and user-friendly functions make it an essential tool for professionals and enthusiasts.

Image 1.1: OWON OW18E Multimeter highlighting its 4½ digit, 20000 counts, True RMS, Bluetooth, Data-logging, AC/DC Current, Diode Test, Capacitance, Temperature, Frequency, Continuity Buzzer, AC/DC Voltage, and Non-Contact Voltage Detect features.
2. Cov ntaub ntawv kev nyab xeeb
Always adhere to safety precautions when using the OWON OW18E Digital Multimeter to prevent electric shock or damage to the device. This multimeter is designed to meet safety standards, but improper use can still lead to hazards.
- Do not exceed the maximum input limits for any measurement range.
- Ensure test leads are properly connected and in good condition before making measurements.
- Avoid touching exposed conductors or circuit components while power is applied.
- Siv Lub Vol Tsis Sib Chwvtage (NCV) function to detect live wires before making contact.
- Hloov cov roj teeb kom sai when the low battery indicator appears to ensure accurate readings and proper operation.
- Do not operate the multimeter if it appears damaged or if the case is open.
- Refer to the complete safety guidelines in the detailed user manual available on the OWON official webqhov chaw.
3. Khoom Tshajview thiab Cheebtsam
Familiarize yourself with the main components of your OWON OW18E Digital Multimeter.

Duab 3.1: Pem hauv ntej view of the OWON OW18E Multimeter, showing the LCD display, Rotary Switch, Bluetooth/Backlight Buttons, Non-Contact Voltage Detect area, Flashlight, 20A current input terminal, mA µA input terminal, V/Ω/Hz/(t)/°C input terminal, and COM input terminal.

Duab 3.2: Rov qab view of the OWON OW18E Multimeter, illustrating the Insulated non-slip case, Test Lead Slot, Retractable Stand, Fuse and 1.5V battery compartment. Insets show the high definition backlit LCD, rotary switch with accurate scale, smooth and fastened sockets, Non-Contact Voltage Detect area, protective sleeve, and storage slot for test leads.
4. Teeb tsa
Before using your multimeter, ensure it is properly set up.
4.1 Kev teeb tsa roj teeb
- Xyuas kom tseeb tias lub multimeter raug tua.
- Locate the battery compartment on the back of the device (refer to Image 3.2).
- Siv lub hau ntswj qhib lub hau roj teeb.
- Insert the required 1.5V batteries (or 9V battery if applicable, as shown in Image 8.1) according to the polarity markings.
- Ua tib zoo kaw lub npog roj teeb.
4.2 Kev Txuas Cov Hlau Ntsuas
- Connect the black test lead to the 'COM' input terminal.
- Connect the red test lead to the appropriate input terminal based on the measurement function:
- Rau Voltage, Resistance, Capacitance, Frequency, Diode, Continuity, and Temperature measurements, connect the red lead to the 'V/Ω/Hz/(t)/°C' terminal.
- For mA or µA current measurements, connect the red lead to the 'mA µA' terminal.
- For 20A current measurements, connect the red lead to the '20A' terminal.
- Xyuas kom meej tias txhua qhov kev sib txuas ruaj khov thiab ruaj ntseg.
5. Cov lus qhia ua haujlwm
This section details how to perform various measurements and utilize the multimeter's functions.
5.1 Kev ntsuas yooj yim
- Voltage (AC/DC) Measurement:
Tig lub rotary hloov mus rau 'V ~' (AC Voltage) or 'V-' (DC Voltage) position. Connect the test leads in parallel to the circuit or component to be measured. The reading will appear on the LCD. - Current (AC/DC) Measurement:
Turn the rotary switch to the 'A~' (AC Current) or 'A-' (DC Current) position, selecting the appropriate range (µA, mA, or 20A). Connect the test leads in series with the circuit. - Kev ntsuas ntsuas:
Turn the rotary switch to the 'Ω' position. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance. - Kev ntsuas Capacitance:
Turn the rotary switch to the 'F' (Capacitance) position. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement. - Kev ntsuas kub:
Turn the rotary switch to the '°C/°F' position. Connect the K-type thermocouple (included) to the input terminals. The temperature will be displayed. - Frequency (Hz) Measurement:
Turn the rotary switch to the 'Hz' position. Connect the test leads to the signal source. - Diode Test:
Turn the rotary switch to the 'Diode' symbol position. Connect the red lead to the anode and the black lead to the cathode of the diode. The forward voltage poob yuav tshwm sim. - Continuity Test:
Turn the rotary switch to the 'Continuity' symbol position. Connect the test leads across the circuit or component. A buzzer will sound if continuity is detected.
5.2 Kev Ua Haujlwm Tshwj Xeeb
- True RMS: The OW18E features True RMS measurement, providing accurate readings for both sinusoidal and non-sinusoidal AC waveforms.
- Tsis Sib cuag Voltage (NCV) Detection: Activate the NCV function to detect the presence of AC voltage without direct contact. The strength indicator will illuminate, and an audible alarm will sound if voltage tau kuaj.
- Backlight: Press the backlight button to illuminate the LCD for improved visibility in low-light conditions.
- Cov ntaub ntawv tuav: Nias lub khawm 'HOLD' kom khov qhov kev nyeem tam sim no ntawm cov zaub. Nias dua kom tso tawm.
- Relative Value Measurement: This function allows you to measure the difference between a current reading and a stored reference value.
- Lub teeb: The built-in flashlight can be activated to illuminate the work area.

Image 5.1: The OWON OW18E demonstrating Non-Contact Voltage Detect, Temperature Measurement with non-contact thermocouple, and the built-in Flashlight. Also shown are calibration tests for standard voltage, resistance, and current measurements.
5.3 Bluetooth Connectivity and Data Logging
The OW18E supports Bluetooth 4.0 for wireless communication with smartphones or PCs, enabling real-time data transfer and logging.

Image 5.2: Bluetooth function introduction, showing voice broadcast measurement support and stable Bluetooth 4.0 transmission for real-time display on mobile phones and PCs. A Bluetooth USB dongle (optional) may be required for PC connection.

Image 5.3: The OWON OW18E functioning as a data-logger, with its app interface displaying logged values in charts and tables. The record interval can be adjusted (default >0.5s). The image also illustrates simultaneous measurement of multiple data sets for analysis and comparison.
5.3.1 Offline Recording Function

Image 5.4: The app interface for the offline recording function. It shows how to set the sample interval (1 to 4,200,000 seconds) and the number of recording points (0 to 10,000 points). After recording, the data is saved in the multimeter's internal memory and can be downloaded to the mobile app for analysis. If the battery is low, the meter will shut down for data protection before the data is downloaded.
For detailed instructions on using the Bluetooth app, please refer to the App Installation Guide included with your product or download the full user manual from the OWON official webqhov chaw: http://www.owon.com.hk/bluetooth4
6. Kev tu
Proper maintenance ensures the longevity and accuracy of your multimeter.
- Ntxuav: Siv lub mos, damp cloth to clean the exterior of the multimeter. Do not use abrasive cleaners or solvents.
- Hloov roj teeb: Replace batteries as soon as the low battery indicator appears to prevent inaccurate readings or device shutdown during critical measurements. Refer to Section 4.1 for battery installation.
- Hloov Fuse: If the current measurement function fails, the fuse may need replacement. Refer to the detailed manual for instructions on accessing and replacing the fuse. Always use a fuse of the specified type and rating.
- Cia: When not in use for extended periods, remove the batteries and store the multimeter in a cool, dry place away from direct sunlight and extreme temperatures.
7. Kev daws teeb meem
If you encounter issues with your OWON OW18E, try the following troubleshooting steps:
| Teeb meem | Ua Tau | Kev daws |
|---|---|---|
| No display or weak display | Lub roj teeb tsawg los yog tsis muaj roj teeb ntsia | Replace or install new batteries. |
| Kev nyeem tsis raug | Incorrect range selected, poor test lead connection, or damaged test leads | Ensure correct range, check test lead connections, or replace test leads. |
| Kev ntsuas tam sim no tsis ua haujlwm | Tshuab fuse | Replace the fuse with the specified type and rating. |
| Bluetooth txuas teeb meem | Bluetooth not enabled, app not installed, or device out of range | Ensure Bluetooth is on, install the OWON app, and keep devices within range. For PC, ensure a Bluetooth dongle is used. |
Yog tias qhov teeb meem tshwm sim tom qab sim cov kev daws teeb meem no, thov hu rau OWON cov neeg siv khoom txhawb nqa.
8. Cov lus qhia tshwj xeeb
The OWON OW18E Digital Multimeter offers the following technical specifications:
| Feature | Specification |
|---|---|
| Cov lej Xam Pom | 20,000 counts (4½ digits) |
| RMS tiag | Yog lawm |
| Bluetooth | Bluetooth 4.0 |
| Cov ntaub ntawv kaw | Up to 10,000 points (offline recording) |
| AC/DC Voltage | Measurement capability included |
| AC / DC Tam Sim No | Measurement capability included (up to 20A) |
| Kev tiv thaiv | Measurement capability included |
| Capacitance | Measurement capability included |
| Kub | Measurement capability included (K-type thermocouple) |
| Ntau zaus | Measurement capability included |
| Diode Xeem | Yog lawm |
| Mus Ntxiv Buzzer | Yog lawm |
| Tsis Sib cuag Voltage (NCV) | Yog lawm |
| Backlight | Yog lawm |
| Teeb nyem | Yog lawm |
| Hwj chim Source | AC (implied by product description, typically battery-powered for handheld) |
| Khoom Dimensions (L x W x H) | 196mm x 88.5mm x 56mm |
| Khoom Net nyhav | 0.32, XNUMX kg |
| Xws li Accessories | Multimeter leads, K-type thermocouple, screwdriver, alligator clips, instructions, app installation guide |

Image 8.1: Product contents and dimensions. Includes the OW18E multimeter, 9V battery (optional), screwdriver, K-type thermocouple, alligator clips, multimeter leads, instructions, and app installation guide. Product dimensions are 196mm x 88.5mm x 56mm, with a net weight of 0.32 kg.
9. Warranty thiab Support
OWON is committed to providing high-quality products and reliable customer support.
9.1 Warranty Information
OWON products purchased through Amazon are covered by a standard warranty:
- Main Unit: 3-year manufacturer's warranty.
- Accessories: 1-year warranty for modules, probes, and batteries.
9.2 Kev Pabcuam Cov Neeg Siv Khoom
For any inquiries, technical assistance, calibration services, repair requests, or other support needs, please contact OWON directly.
- Official Webqhov chaw: User manuals and additional resources can be downloaded from the OWON official webqhov chaw: owon.co.jp
- Hu rau Kev Pabcuam: For calibration, repair, or other service requests, please visit the OWON official website and use the contact form or provided contact information. When requesting repair, please provide your purchase route, purchase date, and model name.
- Bulk Purchases/Demo Units: For corporate customers interested in bulk purchases or borrowing demo units, please contact OWON via their official webqhov chaw.