Taw qhia
This manual provides essential information for the safe and efficient operation of your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater. Please read all instructions carefully before installation, operation, or maintenance. Retain this manual for future reference.

Duab: pem hauv ntej view of the ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, showcasing its compact design and infrared heating plaques.
Cov ntaub ntawv kev nyab xeeb
Your ProCom heater is designed with safety in mind. It is a ventless unit, meaning it does not require an outside duct or chimney. However, proper ventilation is still crucial for safe operation. This heater is equipped with an Oxygen Depletion Sensor (ODS) that automatically shuts down the unit if oxygen levels become too low. It is ANSI Certified to ensure safety standards are met.
- Always ensure adequate air circulation in the room where the heater is operating.
- Do not obstruct the air intake or exhaust vents of the heater.
- Never use this heater in a recreational vehicle or boat.
- Khaws cov khoom uas yooj yim hlawv kom deb ntawm lub tshuab cua sov.
- Regularly inspect the gas connections for leaks.
Khoom nta
- Infrared Heat Technology: Produces 18,000 Maximum BTU, heating up to 950 sq. ft.
- Ventless Design: No outside duct or chimney required.
- Natural Gas Operation: Designed exclusively for natural gas fuel.
- Thermostat tswj: Allows setting to desired comfort level with High/Medium/Low settings.
- Piezo Ignition: Push-button ignition for easy startup, no electricity or batteries required.
- Oxygen Depletion Sensor (ODS): Automatically shuts off the heater if oxygen levels drop.
- Versatile Installation: Can be mounted on a wall or placed on the floor using included base feet.

Image: Diagram highlighting key features of the ProCom heater, including BTU output, ventless operation, natural gas compatibility, no electricity requirement, safety features, Piezo ignition, and thermostat mode.
Teeb tsa
The ProCom MN180TPA-B heater offers flexible installation options: wall-mounted or floor-standing.
Unpacking thiab tshuaj xyuas
- Ua tib zoo tshem tag nrho cov khoom ntim.
- Inspect the heater for any shipping damage. Do not install a damaged unit.
- Xyuas kom meej tias tag nrho cov khoom uas tau teev tseg hauv daim ntawv teev npe muaj nyob.
Xaiv qhov chaw
Select a location that allows for proper clearances from combustible materials. Ensure the area has adequate ventilation as per local codes and the heater's specifications.
Installation Options
Pem Teb Standing: Attach the included base feet to the bottom of the heater using the provided hardware. Ensure the heater is stable and level.
Phab ntsa Mounting: Use the included wall mounting bracket and hardware. Follow the detailed instructions in the manufacturer's full installation guide for secure wall attachment and proper clearances.

Image: Components included with the ProCom heater, showing the main unit, base feet, wall bracket, and highlighting the Oxygen Depletion Sensor and natural gas operation.

Image: The ProCom MN180TPA-B heater mounted on a wall in a living space, demonstrating its compact profile and integration into a room.
Gas kev twb kev txuas
This heater operates on natural gas only. Connection to the natural gas supply must be performed by a qualified professional in accordance with all local codes and regulations. Ensure all connections are leak-tested before operation.
Cov lus qhia ua haujlwm
Follow these steps to safely operate your ProCom MN180TPA-B heater.
Ignition Procedure
- Nco ntsoov tias lub roj av qhib.
- Turn the control knob to the 'PILOT' position.
- Press and hold the control knob in while simultaneously pressing the Piezo ignition button repeatedly until the pilot flame ignites.
- Continue to hold the control knob in for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up. Release the knob; the pilot should remain lit.
- If the pilot does not remain lit, repeat steps 2-4.
- Once the pilot is stable, turn the control knob to the desired heat setting (1-5). The main burner will ignite.
Thermostat Tswj
The heater features a thermostat control with 5 variable heat settings. Rotate the control knob to select your preferred heat output. The heater will cycle on and off to maintain the set temperature.

Duab: Close-up view of the control panel on the ProCom heater, showing the Piezo ignitor button and the rotary knob for 5 variable heat settings and pilot control.
Shutting Down the Heater
- Turn the control knob to the 'OFF' position.
- For prolonged shutdown, close the main gas supply valve to the heater.
Kev tu
Kev saib xyuas tsis tu ncua ua kom koj lub tshuab cua sov ua haujlwm tau ntev thiab muaj kev nyab xeeb.
- Ntxuav: Ensure the heater is completely cool before cleaning. Use a soft, damp cloth to wipe down the exterior. Do not use abrasive cleaners.
- Pilot and Burner Inspection: Periodically inspect the pilot and burner ports for dust or debris. Clean gently with a soft brush if necessary.
- Gas kev sib txuas: Annually check all gas connections for tightness and signs of wear.
- Kev Pabcuam Kev Ua Haujlwm: It is recommended to have the heater inspected by a qualified service technician at least once a year.
Kev daws teeb meem
If you encounter issues with your heater, refer to the following common problems and solutions. For persistent issues, contact a qualified service technician.
| Teeb meem | Ua Tau | Kev daws |
|---|---|---|
| Pilot yuav tsis teeb | No gas supply; Air in gas line; Pilot orifice clogged; Faulty thermocouple | Check gas supply; Purge air from line; Clean pilot orifice; Contact technician |
| Pilot lights but will not stay lit | Thermocouple not heating sufficiently; Loose thermocouple connection; Faulty ODS pilot assembly | Hold knob longer; Tighten connection; Contact technician |
| Main burner will not ignite | Pilot not lit; Main burner orifice clogged; Low gas pressure | Ensure pilot is lit; Clean burner orifice; Contact gas provider/technician |
| Heater cycles off frequently | Insufficient ventilation; ODS activation; Thermostat setting too high for room size | Increase ventilation; Check for obstructions; Adjust thermostat setting |
Specifications
| Yam ntxwv | Paub meej |
|---|---|
| Hom | ProCom |
| Qauv nab npawb | MN180TPA-B |
| Hom roj | Natural Gas |
| Maximum BTU Output | 18,000 XNUMX BTU |
| Kev Pabcuam Cua sov | Txog li 950 sq. ft. |
| Hom Ignition | Push Button Piezo |
| Tswj hom | Thermostat (High/Medium/Low) |
| Kev nyab xeeb nta | Oxygen Depletion Sensor (ODS) |
| Mounting Options | Wall Mount, Floor Standing (Base Feet Included) |
| Khoom Dimensions | 8" H x 22" W x 26" H |
| Yam Nyhav | 26.2 puj |
| Xim | Dawb |
| Cov ntawv pov thawj | CSA Certified, ANSI Certified |

Image: Diagram illustrating the dimensions of the ProCom MN180TPA-B heater: 24 inches H, 19 inches L, and 8 inches D.
Warranty Information
For detailed warranty information regarding your ProCom MN180TPA-B Natural Gas Ventless Infrared Plaque Heater, please refer to the warranty card included with your product packaging or visit the official ProCom webqhov chaw. Warranty cov nqe lus thiab tej yam kev mob yuav txawv.
Kev Pab Txhawb Cov Neeg Siv Khoom
If you require assistance, have questions about your heater, or need to report an issue, please contact ProCom customer support. Refer to your product packaging or the official ProCom website for the most current contact information, including phone numbers, email addresses, and online support resources.