ProLine 116-502

ProLine 116-502 Gas Ball Valve

Phau ntawv qhia

1. Khoom Tshajview

The ProLine 116-502 Gas Ball Valve is a forged brass valve designed for reliable shut-off in natural gas or LP gas applications. It features a durable 1-piece body construction and convenient 3/8-inch flare x flare connections. The valve is equipped with a chrome-plated ball and a quarter-turn lever handle for easy operation. This product is CSA 3-88 certified, ensuring compliance with safety and performance standards for gas appliances.

ProLine 116-502 Gas Ball Valve with yellow lever handle and flare connections.

This image displays the ProLine 116-502 Gas Ball Valve, featuring a brass body, a yellow quarter-turn lever handle, and 3/8-inch flare connections on both ends. The valve is designed for gas applications.

2. Cov ntaub ntawv kev nyab xeeb

CEEB TOOM: Kev teeb tsa tsis raug, hloov kho, hloov kho, kev pabcuam, lossis kev saib xyuas tuaj yeem ua rau muaj kev puas tsuaj, raug mob, lossis tuag. Nyeem cov lus qhia txog kev teeb tsa, kev khiav hauj lwm, thiab kev saib xyuas kom huv si ua ntej txhim kho lossis pab cov cuab yeej no.

  • Nco ntsoov xyuas kom tseeb tias qhov chaw muab roj raug kaw ua ntej kev teeb tsa lossis kev saib xyuas.
  • Installation must be performed by a qualified professional in accordance with all local codes and regulations.
  • Use appropriate tools and personal protective equipment.
  • Check for leaks after installation using a non-corrosive leak detection solution.
  • Do not use open flames to check for gas leaks.
  • This valve is intended for natural gas or LP gas applications only. Do not use for other media.

3. Kev teeb tsa thiab kev teeb tsa

This section provides general guidelines for the installation of the ProLine 116-502 Gas Ball Valve. Always refer to local plumbing and gas codes for specific requirements.

3.1 Pre-Installation Checks

  1. Verify that the valve model 116-502 is suitable for your specific gas application (natural gas or LP gas).
  2. Ensure the connection sizes (3/8-inch flare) match your existing piping.
  3. Inspect the valve for any visible damage before installation. Do not install a damaged valve.
  4. Gather all necessary tools, including wrenches, pipe thread sealant (if applicable for other connections in the system), and leak detection solution.

3.2 Cov kauj ruam installation

  1. Turn off Gas Supply: Locate the main gas shut-off valve and turn off the gas supply to the area where the valve will be installed.
  2. Npaj Kev Sib Txuas: Ensure the flare connections on your gas lines are clean and free of debris.
  3. Connect Valve: Align the valve with the gas lines. Hand-tighten the flare nuts onto the valve's flare connections.
  4. Tighten kev sib txuas: Using appropriate wrenches, carefully tighten the flare nuts. Do not overtighten, as this can damage the flare connections. Refer to manufacturer's recommendations for torque specifications if available, or tighten until snug and then an additional quarter to half turn.
  5. Restore Gas Supply: Slowly turn the main gas supply back on.
  6. Tshawb xyuas Leaks: Apply a non-corrosive leak detection solution to all new connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, re-tighten the connection, and re-test. Repeat until no leaks are present.

4. Cov lus qhia ua haujlwm

The ProLine 116-502 Gas Ball Valve is designed for simple on/off operation.

  • Yuav Qhib Lub Valve li cas: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is parallel with the gas flow direction.
  • Yuav kaw lub Valve li cas: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is perpendicular to the gas flow direction.

The quarter-turn design allows for quick and easy visual confirmation of the valve's open or closed status.

5. Kev tu

The ProLine 116-502 Gas Ball Valve is designed for long-term, maintenance-free operation under normal conditions. Regular inspection is recommended.

  • Kev tshuaj xyuas lub sijhawm: Visually inspect the valve and connections periodically for any signs of corrosion, damage, or leaks.
  • Leak Checks: If you suspect a leak, perform a leak check using a non-corrosive leak detection solution.
  • Ntxuav: Clean the exterior of the valve with a damp cloth if necessary. Do not use harsh chemicals or abrasive cleaners.
  • Tsis siv neeg-Serviceable Parts: This valve contains no user-serviceable parts. Do not attempt to disassemble or repair the valve. If the valve is damaged or malfunctioning, it must be replaced by a qualified professional.

6. Kev daws teeb meem

This section addresses common issues that may arise with gas ball valves. Always prioritize safety and consult a professional for any complex issues.

  • Gas Leak Detected:
    • Cov tsos mob: Smell of gas, or bubbles when leak detection solution is applied.
    • Kev Ua: Immediately turn off the main gas supply. Re-check all connections for proper tightening. If the leak persists, do not attempt further repairs. Contact a qualified gas technician.
  • Valve Difficult to Turn:
    • Cov tsos mob: Lever handle is stiff or hard to rotate.
    • Kev Ua: Do not force the handle. Excessive force can damage the valve. If the valve is new, it may be slightly stiff initially. If it becomes stiff over time, it may indicate internal wear or debris. The valve should be replaced by a qualified professional.
  • Tsis Muaj Pa Roj:
    • Cov tsos mob: Appliance not receiving gas, even with valve in open position.
    • Kev Ua: Ensure the valve handle is fully parallel to the pipe (open position). Check other shut-off valves in the system and the main gas supply. If the issue persists, contact a qualified gas technician.

7. Cov lus qhia tshwj xeeb

SpecificationPaub meej
Qauv nab npawb116-502 : kuv
HomProLine
Khoom sivForged Brass (Chrome Plated Ball)
Hom kev sib txuasFlare x Flare
Kev sib txuas loj3/8 po x 3/8 po
Kev ua haujlwmQuarter-Turn Lever Handle
Cov ntawv pov thawjCSA 3-88
Daim ntawv thovNatural Gas lossis LP Gas
Yam Nyhav3.7 phaus (rau 10-pob)
Khoom Dimensions (L x W x H)7.28 x 4.53 x 2.95 nti (rau 10-pob)
Chaw tsim tshuaj pausB&K LLC

8. Warranty Information

For specific warranty details regarding the ProLine 116-502 Gas Ball Valve, please refer to the official ProLine website or contact their customer service directly. Warranty terms typically cover manufacturing defects under normal use and service.

9. Cov neeg siv khoom txhawb nqa

If you have any questions, require technical assistance, or need to report an issue with your ProLine 116-502 Gas Ball Valve, please contact ProLine customer support through their official channels. Always provide the model number (116-502) when seeking support.

Yog xav paub ntxiv, koj mus saib tau rau ntawm ProLine brand page on Amazon.

© 2024 ProLine. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.