OLMO OW-P08HS115WF/ OW-TTWSLV

OLMO Through-the-Wall Air Conditioner & Heat System User Manual

Model: OW-P08HS115WF/ OW-TTWSLV

Taw qhia

Thank you for choosing the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System. This unit is designed to provide efficient heating and cooling for residential, commercial, or hotel use. It features a built-in wireless smart kit for convenient control via smartphone, an included remote control, and comes with a wall sleeve for installation.

This manual provides essential information for the safe and effective setup, operation, and maintenance of your OLMO unit. Please read it thoroughly before installation and use.

OLMO Through-the-Wall Air Conditioner unit with remote control, smartphone app, and wall sleeve.

Figure 1: OLMO Through-the-Wall Air Conditioner and included accessories.

Kev teeb tsa thiab kev teeb tsa

The OLMO Through-the-Wall Air Conditioner is designed for packaged installation. A wall sleeve is included with your unit to facilitate proper mounting.

Pre-Installation Checklist:

  • Verify power supply: This unit requires a 115V, 1-phase, 60Hz power supply. Ensure you have the correct receptacle.
  • Check dimensions: The product dimensions are approximately 20.28 x 24.21 x 14.53 inches. Ensure your wall opening is appropriately sized for the unit and wall sleeve.
  • Confirm refrigerant: The unit is pre-charged with R-32 refrigerant.

Wall Sleeve Installation:

The included wall sleeve (Model: OW-TTWSLV) is crucial for secure and proper installation. Follow the detailed instructions provided in the separate installation guide for precise measurements and mounting procedures. Proper sealing and insulation around the sleeve are essential for optimal performance and energy efficiency.

White metal wall sleeve for through-the-wall air conditioner.

Figure 2: Included Wall Sleeve (OW-TTWSLV).

Chav nyob qhov chaw:

Ensure the unit is installed in a location that allows for proper airflow around the intake and exhaust vents. Avoid placing objects directly in front of or on top of the unit that could obstruct air circulation.

Cov lus qhia ua haujlwm

Your OLMO Through-the-Wall unit offers multiple control options for your convenience:

  • Digital Push Button Control Panel: Located on the unit with an LED display for direct control.
  • Included Remote Controller: Muab tag nrho cov kev ua haujlwm los ntawm qhov deb.
  • Built-In Wireless Smart Kit: Allows control via a compatible smartphone application.

Chaw taws teeb tswj muaj nuj nqi:

The remote control allows you to adjust temperature, change modes (Cool, Heat, Fan, Dry, Auto), set fan speeds, and activate special features like Sleep Mode and Timer.

White remote control for OLMO air conditioner with various buttons for mode, fan speed, temperature, and timer.

Figure 3: Remote Control for OLMO AC Unit.

Smart Connect (Wi-Fi) Operation:

The built-in Smart Connect feature enables you to control your unit remotely using a smartphone app. Download the official OLMO app from your device's app store and follow the in-app instructions to pair your unit. This allows for convenient control from anywhere with an internet connection.

A hand holding a smartphone displaying the OLMO air conditioner control app interface.

Figure 4: Smartphone App for Smart Control.

Cov yam ntxwv tseem ceeb:

  • Hom pw tsaug zog: Kho qhov kub thiab txias tau rau kev pw tsaug zog zoo thiab txuag hluav taws xob.
  • Pib Pib Pib: The unit will automatically restart with previous settings after a power outage.
  • Ntau Ntxuam Ceev: Xaiv los ntawm ntau yam kev ceev ntawm lub kiv cua rau kev hloov kho cua.
  • Timer: Program lub tshuab kom qhib lossis kaw thaum lub sijhawm tshwj xeeb.
  • Self-Evaporative System: Helps manage condensate, reducing the need for manual draining in most conditions.
  • LED Zaub: Muab qhia meej txog qhov chaw teeb tsa thiab xwm txheej ua haujlwm.
  • Fresh Air Input: Allows for introduction of fresh outdoor air.

Video: Tshajview of OLMO Through-the-Wall Air Conditioner features and capabilities. This video demonstrates the unit's design and highlights its smart connectivity and remote control options.

Kev tu

Regular maintenance ensures optimal performance and longevity of your OLMO air conditioner. Always disconnect power to the unit before performing any maintenance.

Cua Lim Cleaning:

The air filter should be cleaned every two weeks, or more frequently depending on usage and air quality. A dirty filter can reduce cooling/heating efficiency and airflow.

  1. Qhib lub vaj huam sib luag pem hauv ntej ntawm lub tshuab.
  2. Carefully remove the air filter(s).
  3. Ntxuav lub lim nrog dej sov, xab npum. Yaug kom huv si.
  4. Allow the filter to air dry completely before reinserting. Do not expose to direct sunlight or heat.

Kev Tu Nthuav dav:

So sab nrauv ntawm chav tsev nrog ib qho mos mos, damp cloth. Do not use harsh chemicals, abrasives, or solvents, as these can damage the surface. Ensure the drainage area is clear of debris.

Kev daws teeb meem

If you experience issues with your OLMO air conditioner, refer to the following common troubleshooting steps. For problems not listed here, or if issues persist, please contact OLMO customer support.

Teeb meemUa TauKev daws
Unit tsis qhibNo power supply; Circuit breaker tripped; Unit unplugged.Check power cord connection; Reset circuit breaker; Ensure unit is plugged into a functional 115V outlet.
Tsis txaus cua txias / cua sovDirty air filter; Obstructed airflow; Temperature setting too high/low; Room size exceeds capacity.Clean air filter; Remove obstructions from vents; Adjust temperature setting; Ensure unit capacity matches room size.
Unit tsis nrovLoose parts; Unit not level; Fan obstruction.Check for loose components; Ensure unit is level; Inspect fan for obstructions.
Kev tswj chaw taws teeb tsis ua haujlwmCov roj teeb tuag lawm; Muaj kev cuam tshuam ntawm chaw taws teeb thiab lub tshuab.Hloov cov roj teeb; Xyuas kom meej meej ntawm qhov pom mus rau chav tsev receiver.

Specifications

Detailed technical specifications for the OLMO 8,000 BTU 115V Through-the-Wall Air Conditioner and Heat System (Model: OW-P08HS115WF/ OW-TTWSLV).

SpecificationTus nqi
Hom Lub NpeELM
Qauv InfoOW-P08HS115WF/ OW-TTWSLV
Yam Nyhav80 puj
Khoom Dimensions (D x W x H)20.28 x 24.21 x 14.53 po
Lub Tebchaws Keeb KwmTuam Tshoj
Kev ua tau zooZoo
Muaj peev xwm0.66 ton
Lub suab nrov52dB ua
Hom kev teeb tsaPackaged, Through-the-Wall
Tshwj xeeb ntaRemote Controlled, WiFi Enabled
Cov Cuab Yeej Cuab Yeej1
XimDawb
Voltage115 Volts
Cov Cheebtsam suav nrogThrough the Wall Air Conditioner, Wall Sleeve and Remote Control
Lub zog txias8000 British Thermal Units
Cov tub yeesR-32
Detailed technical specifications table for various OLMO Through-the-Wall AC models, including power, capacity, EER, current, noise, and dimensions.

Figure 5: Comprehensive Technical Specifications Table.

Warranty thiab Support

For technical assistance, warranty inquiries, or further support, please contact OLMO customer service. Refer to your product packaging or the official OLMO website rau cov ntaub ntawv tiv tauj tam sim no.

You can also visit the official OLMO store for more product information and resources: OLMO Store on Amazon.

© 2024 OLMO. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.